DS1054-057
P
With wireless connection (via Yokis MTR module) to the solenoid valves and to the boiler. The installer is
responsible for managing the OR function of the boiler again in this case and this is usually achieved by
means of solenoid valves which have a dedicated electrical output which is energised when the solenoid
valve is open.
With wireless connection (via Yokis MTR module) to the solenoid valves and boiler. In this case, no specific
wiring is needed to implement the OR function. However, the presence of a Yokis Hub is indispensable in
the system.
Case A)
Simply follow the instructions in the two previous paragraphs for each thermostat according to whether or not
you use the Yokis PRO app for configuration:
Single-zone thermostat configuration with direct wiring
YOKIS PRO: Single-zone thermostat configuration with direct wiring
However, in this case it is necessary to prepare the wiring from each thermostat to its own zone solenoid valve
and also to manage the OR function towards the boiler using the usual wiring techniques (mainly using solenoid
valves with dedicated output).
Note:
When configured in this way, the thermostat cannot be accessed remotely or locally via the Yno app. To
be so, a Yokis Hub must also be also installed in the system.
Case B)
Simply follow the instructions in the two previous paragraphs for each thermostat according to whether or not
you use the Yokis PRO app for configuration:
Single-zone thermostat configuration with wireless connection (via MTR) and check
YOKIS PRO: Single-zone thermostat configuration with wireless connection (via MTR)
However, in this case it is necessary to prepare the wiring from each thermostat to its own zone solenoid valve
and also to manage the OR function towards the boiler using the usual wiring techniques (mainly using solenoid
valves with dedicated output).
Note:
When configured in this way, the thermostat cannot be accessed remotely or locally via the Yno app. To
be so, a Yokis Hub must also be also installed in the system.
Case C)
Four steps are required in this case:
Add the MTR modules which will control the zone solenoid valves.
Add an additional MTR to control the boiler (in OR mode).
Add and configure the thermostats, one for each zone. Thermostats are all considered as the Control
Points by the app.
Connect each thermostat to its own MTR actuator module (for the solenoid valve in your area) AND to
the boiler MTR module.
The MTR modules must be added to the Yokis PRO app in the usual way (automatic or manual detection).
However, it is necessary to specialise their function. Therefore, all MTRs which will be connected to the zone
solenoid valves must use the motorised valve symbol: