P
DS1054-057
On the screen that appears, select the MTR with the boiler symbol, previously added and confirm.
Store the settings by pressing “Store”.
Go back to the point on the previous page, you must now transfer the configuration from the App to the
thermostat. To do this, similarly to what you are used to do with a remote control, tap on the button at the
bottom right, “Program” and, on the thermostat, press the button
twice.
At the end of the transfer, “PASS” will be briefly displayed on the thermostat. If the transfer was not successful,
“Err 16” will appear instead. Try again, in this case.
Note:
When configured in this way, the thermostat cannot be accessed remotely or locally via the Yno app. To
be so, a Yokis Hub must also be also installed in the system.
10.4.6. Configuration of multiple thermostats, one in each zone, in a multi-zone
system
This is typically the case in a single-family house with several floors, where the heating is managed by means of a
zone solenoid valve and the temperature is controlled by a dedicated thermostat on each floor.
Solenoid valves
In this case, it is worth noting when a thermostat controls the opening of its own solenoid valve, it is necessary
to ensure that the boiler and its circulation pump also come into operation.
This is called OR operation, because the boiler must come into operation when:
either solenoid valve 1
or
solenoid valve 2 is open
Three installation solutions are possible
With direct connection of the thermostats to the solenoid valves. In this case, the installer is responsible for
managing the boiler in OR mode. This is usually achieved by means of solenoid valves which have a dedica-
ted electrical output which is energised when the solenoid valve is open.
A.