Process
Parameter
Description
220V
110V
Default
DC TIG
PRE GAS
Pre-flow
0.1~15s
0.1~15s
0.3s
Istart
Initial Current
5~160A
5~80A
15A
SLOPE UP
UpSlope Time
0~10s
0~10s
0s
I1
Peak Current
5-200A
5~160A
50A
SLOPPE DOWN
Downslope Time
0~15s
0~15s
0s
Istop
Crater Current
5~200A
5~100A
15A
POST GAS
Post-flow
0.1~15s
0.1~15s
2s
Pulse TIG Welding
Fig 15 DC Pulse TIG Current Change Waveform
In pulse TIG mode, all DC TIG parameters except current (I3), could check the description above DC TIG Welding. There are 4 dif-
ferent adjustable parameters in this process. Describe them as below.
Ÿ
Peak Current (Ip):
It should be adjusted according to users' technical requirements.
Ÿ
Background Current (Ib):
It should be adjusted according to users' technical requirements.
Ÿ
Pulsed Frequency (1/T):
T=Tp+Tb. It should be adjusted according to users' technical requirements.
Ÿ
Pulse Duration Ratio (Pulse Width (100%*Tp/T):
The percentage peak current time holding in pulse period. It should be ad-
justed according to users' technical requirements.
Upslope
Welding Current
I
1
Initial
Preset
Downslope
Pilot arc
O
tp
tb
T
I
b
I
5
I
p
t
I
DC TIG Parameters
DC Pulse TIG
23
The actual parameter can be flexibly selected according to actual workpiece thickness and technology.
Process
Parameter
Description
220V
110V
Default
DC Pulse TIG
PRE GAS
Pre-flow
0.1~15s
0.1~15s
0.3s
Istart
Initial Current
5~160A
5~80A
15A
SLOPE UP
UpSlope Time
0~10s
0~10s
0s
I1
Peak Current
5-200A
5~160A
50A
I2
Background Current
I1*10%-I1 A
I1*10%-I1 A
50A
PULSE(Hz)
Pulse Frequency
0.2-200Hz
0.2-200Hz
0.5Hz
DUTY CYCLE (I1:I2)
Pulse Width
10%-90%
10%-90%
SLOPPE DOWN
Downslope Time
0-15s
0-15s
0s
Istop
Crater Current
5-200A
5-100A
15A
POST GAS
Post-flow
0.1-15s
0.1-15s
2s
Summary of Contents for CT2050