![background image](http://html1.mh-extra.com/html/yealink/t5-series/t5-series_administrators-manual_3764184305.webp)
Audio Features
299
Parameter
phone_setting.vq_rtcpxr.session_report.enable
<y0000000000xx>.cfg
Description
It enables or disables the phone to send a session quality report to the central report collector at the end
of each call.
Permitted
Values
0
-Disabled
1
-Enabled
Default
0
Web UI
Settings->Voice Monitoring->VQ RTCP-XR Session Report
Parameter
phone_setting.vq_rtcpxr.interval_report.enable
<y0000000000xx>.cfg
Description
It enables or disables the phone to send an interval quality report to the central report collector peri-
odically throughout a call.
Permitted
Values
0
-Disabled
1
-Enabled
Default
0
Web UI
Settings->Voice Monitoring->VQ RTCP-XR Interval Report
Parameter
phone_setting.vq_rtcpxr_interval_period
<y0000000000xx>.cfg
Description
It configures the interval (in seconds) for the phone to send an interval quality report to the central report
collector periodically throughout a call.
Note
: It works only if “phone_setting.vq_rtcpxr.interval_report.enable” is set to 1 (Enabled).
Permitted
Values
Integer from 5 to 20
Default
20
Web UI
Settings->Voice Monitoring->Period for Interval Report
Parameter
phone_setting.vq_rtcpxr_moslq_threshold_warning <y0000000000xx>.cfg
Description
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold value
of MOS-LQ causes the phone to send a warning alert quality report to the central report collector.
For example, a configured value of 35 corresponds to the MOS score 3.5. When the MOS-LQ value com-
puted by the phone is less than or equal to 3.5, the phone will send a warning alert quality report to the
central report collector. When the MOS-LQ value computed by the phone is greater than 3.5, the phone
will not send a warning alert quality report to the central report collector.
If it is set to blank, warning alerts are not generated due to MOS-LQ.
Permitted
Values
15 to 40
Default
Blank
Web UI
Settings->Voice Monitoring->Warning threshold for Moslq
Parameter
phone_setting.vq_rtcpxr_moslq_threshold_critical
<y0000000000xx>.cfg
Description
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold value
of MOS-LQ causes the phone to send a critical alert quality report to the central report collector.
For example, a configured value of 28 corresponds to the MOS score 2.8. When the MOS-LQ value com-
puted by the phone is less than or equal to 2.8, the phone will send a critical alert quality report to the
central report collector. When the MOS-LQ value computed by the phone is greater than 2.8, the phone
Summary of Contents for T5 Series
Page 1: ......
Page 26: ...20 Administrator s Guide for SIP T58V T58A T56A CP960 IP Phones ...
Page 58: ...52 Administrator s Guide for SIP T58V T58A T56A CP960 IP Phones ...
Page 86: ...80 Administrator s Guide for SIP T58V T58A T56A CP960 IP Phones ...
Page 88: ...82 Administrator s Guide for SIP T58V T58A T56A CP960 IP Phones ...
Page 316: ...310 Administrator s Guide for SIP T58V T58A T56A CP960 IP Phones ...
Page 388: ...382 Administrator s Guide for SIP T58V T58A T56A CP960 IP Phones ...
Page 464: ...458 Administrator s Guide for SIP T58V T58A T56A CP960 IP Phones ...