VS-616G5 Programming Manual
Section E: Motor Parameters
E4 Motor 2 V/F Pattern / E5 Motor 2 Set-up
The motor 2 parameters are identical to the motor 1 parameters. Refer to E1-03 through E1-10.
E5
Motor 2 Set-up
Sets the motor rated current in units of 0.01A for inverter models 27P5, 47P5 and smaller; 0.1A for
models G5U2011, G5U4011 and larger. The default setting varies depending on the inverter model set-
ting (O2-04).
Setting range:
0.00 to 20.00Hz
Sets the motor rated slip frequency in units of 0.01Hz. The default setting varies depending on the
inverter model setting (O2-04). Use the following equation to calculate the motor rated slip frequency:
Sets the motor no-load current in units of 0.01A for inverter models 27P5, 47P5 and smaller; 0.1A for
models G5U2011, G5U4011 and larger. The default setting varies depending on the inverter model set-
ting (O2-04).
Setting Range:
2 to 48 poles
Factory Default:
4 poles
Sets the number of motor poles for motor 2.
E4-01 Motor 2 Maximum Frequency
Max Frequency
A
A
A
A
E4-02 Motor 2 Maximum Voltage
Max Voltage
A
A
A
A
E4-03 Motor 2 Base Frequency
Base Frequency
A
A
A
A
E4-04 Motor 2 Middle Output Frequency A
Mid Frequency A
A
A
A
−
E4-05 Motor 2 Middle Output Voltage A
Mid Voltage A
A
A
A
−
E4-06 Motor 2 Minimum Output Frequency
Min Frequency
A
A
A
A
E4-07 Motor 2 Minimum Output Voltage
Min Voltage
A
A
AA
−
E5-01 Motor 2 Rated Current
Motor Rated FLA
A
A
A
A
E5-02 Motor 2 Rated Slip Frequency
Motor Rated Slip
A
A
A
A
E5-03 Motor 2 No-Load Current
No-Load Current
A
A
A
A
E5-04 Motor 2 Number of Motor Poles
Number of Poles
−
A
−
A
where:
f
s
f
N P
⋅
(
)
120
-----------------
–
=
f : slip frequency (Hz)
f : rated frequency (Hz)
N : rated motor speed (rpm)
P : number of motor poles
s