6.4 Drive Cooling Fans
6.4
Drive Cooling Fans
NOTICE:
Follow cooling fan replacement instructions. The cooling fan cannot operate properly when
installed incorrectly and could seriously damage the drive. To ensure maximum useful product life, replace
all cooling fans when performing maintenance.
Contact your Yaskawa representative or supplier to order replacement cooling fans as
required.
Some drive models have multiple cooling fans.
For drives with multiple cooling fans, replace all the fans when performing maintenance to
ensure maximum useful product life.
◆
Cooling Fan Replacement
The cooling fan is installed on the top of the drive. The cooling fan can easily be replaced
without tools or removal of the drive or enclosure parts.
WARNING!
Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to
comply can result in serious personal injury. Before servicing the drive, disconnect all power to the
equipment. The internal capacitor remains charged even after the power supply is turned off. The charge
indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at
least five minutes after all indicators are OFF and measure the DC bus voltage level to confirm safe level.
CAUTION!
Burn Hazard. Do not touch a hot drive heatsink. Failure to comply could result in minor or
moderate injury. Shut off the power to the drive when replacing the cooling fan. To prevent burns, wait at
least 15 minutes and ensure the heatsink has cooled down.