WARNING
Do not use an improper voltage source.
Failure to comply could result in death or serious injury by fire.
Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power.
CAUTION
Do not carry the drive by the front cover or the terminal cover.
Failure to comply may cause the main body of the drive to fall, resulting in minor or moderate injury.
NOTICE
Perform a final check of all sequence wiring and other connections prior to applying power.
Failure to comply may cause erroneous operation or damage to the drive.
Ensure there are no short circuits on the control terminals.
Failure to comply may damage the drive.
Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit boards.
Failure to comply may result in ESD damage to the drive circuitry.
Never connect or disconnect the motor from the drive while the drive is outputting voltage.
Improper equipment sequencing could result in damage to the drive.
Do not use unshielded cable for control wiring.
Failure to comply may cause electrical interference resulting in poor system performance. Use shielded, twisted-pair wires
and ground the shield to the ground terminal of the drive.
Use ring terminals that comply with UL/cUL for all wire ends.
Failure to comply may damage the drive.
Use only the tools recommended by the terminal manufacturer for crimping.
Failure to comply may damage the drive.
Do not allow unqualified personnel to use the product.
Failure to comply may damage the drive.
Carefully review instruction manual when connecting, wiring, or replacing the drive.
Do not modify the drive circuitry.
Failure to comply may damage the drive and will void warranty.
Yaskawa is not responsible for any modification of the product made by the user. This product must not be modified.
Check all the wiring to ensure that all connections are correct after installing the drive and connecting any other
devices.
Failure to comply may damage the drive.
Comply with proper wiring practices
The motor may run in reverse if the phase order is incorrect.
Connect motor input terminals U, V, and W to drive output terminals U/T1, V/T2, and W/T3. The phase order for the drive
and motor should match.
3.1 Section Safety
YASKAWA TOEPYAIUPW01A YASKAWA AC Drive - U1000 iQpump Matrix Drive User Manual
51
3
Electrical Installation