6.2 List of Servo Parameters
6-37
6
Parameter Li
s
t
s
Pn868
2
SVCMD_IO Output Sig-
nal Monitor Allocations
1
0000h to
1717h
–
0000h
Rotary
Immedi-
ately
Setup
*2
Pn869
2
SVCMD_IO Output Sig-
nal Monitor Allocations
2
0000h to
1717h
–
0000h
Rotary
Immedi-
ately
Setup
*2
Pn87A
4
Last Rotational Coordi-
nate
0 to
536,870,911
1 refer-
ence
unit
0
Rotary
After
restart
Setup
Pn87C
4
First Rotational Coordi-
nate
-536,870,912
to 0
1 refer-
ence
unit
0
Rotary
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
M3
*8
n.
X
Output Signal Monitor Allocation for CN1-1 and CN1-2 (SVCMD_IO)
0
Allocate bit 24 (IO_STS1) to CN1-1/CN1-2 output signal monitor.
1
Allocate bit 25 (IO_STS2) to CN1-1/CN1-2 output signal monitor.
2
Allocate bit 26 (IO_STS3) to CN1-1/CN1-2 output signal monitor.
3
Allocate bit 27 (IO_STS4) to CN1-1/CN1-2 output signal monitor.
4
Allocate bit 28 (IO_STS5) to CN1-1/CN1-2 output signal monitor.
5
Allocate bit 29 (IO_STS6) to CN1-1/CN1-2 output signal monitor.
6
Allocate bit 30 (IO_STS7) to CN1-1/CN1-2 output signal monitor.
7
Allocate bit 31 (IO_STS8) to CN1-1/CN1-2 output signal monitor.
n.
X
CN1-1/CN1-2 Output Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-1/CN1-2 output signal monitor.
1
Enable allocation for CN1-1/CN1-2 output signal monitor.
n.
X
Output Signal Monitor Allocation for CN1-23 and CN1-24 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-1/CN1-2 allocations.
n.X
CN1-23/CN1-24 Output Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-23/CN1-24 output signal monitor.
1
Enable allocation for CN1-23/CN1-24 output signal monitor.
M3
*8
n.
X
Output Signal Monitor Allocation for CN1-25 and CN1-26 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-1/CN1-2 allocations.
n.
X
CN1-25/CN1-26 Output Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-25/CN1-26 output signal monitor.
1
Enable allocation for CN1-25/CN1-26 output signal monitor.
n.
X
Reserved parameter (Do not change.)
n.X