6.2 List of Servo Parameters
6-6
Pn009
2
Application Function
Selections 9
0000h to
0121h
–
0010h
Rotary
After
restart
Tuning
*1
Pn00A
2
Application Function
Selections A
0000h to
0044h
–
0001h
Rotary
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Reserved parameter (Do not change.)
n.
X
Current Control Mode Selection
0
Use current control mode 1.
1
•
SERVOPACK Models SGD7S-2R8A and -2R8F: Use current control mode 1.
•
SERVOPACK Model: SGD7S-120A: Use current control mode 2.
2
Use current control mode 2.
n.
X
Speed Detection Method Selection
0
Use speed detection 1.
1
Use speed detection 2.
n.X
Reserved parameter (Do not change.)
n.
X
Motor Stopping Method for Group 2 Alarms
0
Apply the dynamic brake or coast the motor to a stop (use the stopping
method set in Pn001 = n.
X).
1
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
torque. Use the setting of Pn001 = n.
X for the status after stopping.
2
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
the setting of Pn001 = n.
X for the status after stopping.
4
Decelerate the motor to a stop using the deceleration time set in Pn30A and
then let the motor coast.
n.
X
Stopping Method for Forced Stops
0
Apply the dynamic brake or coast the motor to a stop (use the stopping
method set in Pn001 = n.
X).
1
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
torque. Use the setting of Pn001 = n.
X for the status after stopping.
2
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
the setting of Pn001 = n.
X for the status after stopping.
4
Decelerate the motor to a stop using the deceleration time set in Pn30A and
then let the motor coast.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)