REVIEWING THE FULL-CLOSED LOOP SPECIFICATIONS
494
* Number of Full–closed Pulses
=
Cn–2A
=
4
0.01
×
10
25
×
6
=
4
×
25
×
6
0.01
×
10
=
6000P
∕
rev
. * Memory switch Cn-02 Bit B =1
Conditions except above are the same as those of position control at full-closed speci-
fications.
•
Reviewing the above data, full-closed loop can be applicable under the above condi-
tions.
G