Digital Operator 3 - 15
Table 3.14 Changing a Parameter in the Programming Menu
Step
Number
Digital Operator Display
Description
8
Press the INCREASE key to display C1-02 (Decel Time 1).
9
Press the DATA/ENTER key to access setting display.
10
Press the SHIFT/RESET key to move the flashing digit to the right.
11
Press the SHIFT/RESET key to move the flashing digit to the right.
12
Press the INCREASE key to increase the set data.
13
Press the DATA/ENTER key to enter the set data. “Entry Accepted” is dis-
played for 1.0 sec after the data setting has been confirmed.
14
The monitor display for C1-02 returns.
15
Press the MENU key to scroll to “Operation” menu.
16
Press the DATA/ENTER key to enter “Operation” menu.
-ADV-
Decel Time 1
- - - - - - - - - - - - - - - - - - - -
C1-
02
= 30.0sec
(0.0~6000.0)
“30.0sec”
-ADV-
Decel Time 1
- - - - - - - - - - - - - - - - - - - -
C1-02=
0
030.0sec
(0.0~6000.0)
“30.0sec”
-ADV-
Decel Time 1
- - - - - - - - - - - - - - - - - - - -
C1-02= 0
0
30.0sec
(0.0~6000.0)
“30.0sec”
-ADV-
Decel Time 1
- - - - - - - - - - - - - - - - - - - -
C1-02= 00
3
0.0sec
(0.0~6000.0)
“30.0sec”
-ADV-
Decel Time 1
- - - - - - - - - - - - - - - - - - - -
C1-02= 00
4
0.0sec
(0.0~6000.0)
“30.0sec”
-ADV-
Entry Accepted
-ADV-
Decel Time 1
- - - - - - - - - - - - - - - - - - - -
C1-
02
= 30.0sec
(0.0~6000.0)
“30.0sec”
40.0sec
-DRIVE-
** Main Menu **
- - - - - - - - - - - - - -
Operation
-DRIVE- Rdy
Frequency Ref
U1-
01
= 0.00Hz
- - - - - - - - - - - - - - - - - - - -
U1-02= 0.00Hz
U1-03= 0.00A
Summary of Contents for P7
Page 1: ...P7 Drive User Manual Model P7U Document Number TM P7 01...
Page 58: ...Electrical Installation 2 30...
Page 74: ...Digital Operator 3 16...
Page 84: ...Start Up 4 10 Notes...
Page 144: ...Programming 5 60 Notes...
Page 210: ...Capacity Related Parameters B 6 Notes...
Page 238: ...Spare Parts F 4 Notes...
Page 244: ...EMC Compatibility G 6 Notes...