Digital Operator 3 - 14
Example of Changing a Parameter
Table 3.14 provides an example of how to change parameter “C1-02” (Deceleration Time 1) from 30 seconds to 40 seconds.
Table 3.14 Changing a Parameter in the Programming Menu
Step
Number
Digital Operator Display
Description
1
The Drive is first powered up.
2
Press the MENU key to scroll to “Operation” menu.
3
Press the MENU key to scroll to “Quick Setting” menu.
4
Press the MENU key to scroll to “Programming” menu.
5
Press the DATA/ENTER key to enter “Programming” menu.
6
Press the INCREASE key until C1-01 (Accel/Decel) is displayed.
7
Press the SHIFT/RESET key to move flashing digit to the right.
-DRIVE- Rdy
Frequency Ref
U1-
01
= 0.00Hz
- - - - - - - - - - - - - - - - - - - -
U1-02= 0.00Hz
U1-03= 0.00A
-DRIVE-
** Main Menu **
- - - - - - - - - - - - - -
Operation
-QUICK-
** Main Menu **
- - - - - - - - - - - - - -
Quick Setting
-ADV-
** Main Menu **
- - - - - - - - - - - - - -
Programming
-ADV-
Initialization
- - - - - - - - - - - - - - - - - - - -
A1
-01= 0
Select Language
-ADV-
Accel/Decel
- - - - - - - - - - - - - - - - - - - -
C1
-01= 1.0sec
Accel Time 1
-ADV-
Accel Time 1
- - - - - - - - - - - - - - - - - - - -
C1-
01
= 30.0sec
(0.0~6000.0)
“30.0sec”