4 Keypad Operation
YASKAWA Europe
TOEP C710606 50B - AC Drive L1000V - Quick Start Guide
EN 23
4
Keypad Operation
LED Operator and Keys
The LED operator is used to program the drive, to start/
stop it, and to display fault information. The LEDs
indicate the drive status.
Keys and Functions
Display
Name
Function
Data Display Area Displays the frequency reference, parameter number, etc.
ESC Key
Returns to the previous menu.
RESET Key
Moves the cursor to the right.
Resets a fault.
RUN Key
The Run LED is on, when the drive is operating the motor.
Flashes when decelerating to stop or when the frequency reference is 0.
Flashes quickly when the drive is disabled by a DI, the drive was stopped using a
fast stop DI, or a run command was active during power up.
Up Arrow Key
Scrolls up to display the next item, selects parameter numbers and increments
setting values.
Down Arrow Key
Scrolls down to display the previous item, selects parameter numbers and
decreases setting values.
STOP Key
Stops the drive.
ENTER Key
Selects modes, parameters and is used to store settings.
ALM LED Light
Flashing: The drive is in an alarm state.
On: The drive is in a fault state and the output is stopped.
REV LED Light
On: The motor rotation direction is reverse.
Off: The motor rotation direction is forward.
DRV LED Light
On: The drive is ready to operate the motor.
Off: The drive is in the Verify, Setup, Parameter Setting or Auto tuning mode.
FOUT LED Light
On: The output frequency is displayed on the data screen.
Off: Something other than the output frequency is displayed on the data screen.
STOP
RUN
STOP
ALM
REV
DRV
FOUT