7 Parameter Table
EN 40
YASKAWA Europe
TOEP C710606 50B - AC Drive L1000V - Quick Start Guide
Carrier Frequency
C6-02
Carrier Fre-
quency
Sets the carrier frequency. Settings
above the default requires output
current derating.
Speed Reference
d1-01
to d1-
08
Speed Ref-
erence 1 to
8
Speed reference values for multi-
speed inputs.
d1-18
Speed Ref-
erence
Selection
0: Multi-speed references 1 to 8
1: Higher speed reference has
priority
2: Leveling speed reference has
priority
d1-19
Nominal
Speed
Speed reference values for separate
speed selection inputs.
d1-20
Intermedi-
ate Speed 1
d1-21
Intermedi-
ate Speed 2
d1-22
Intermedi-
ate Speed 3
d1-23
Relevel.
Speed
d1-24
Inspection
Operation
Speed
d1-26
Leveling
Speed
d1-28
Leveling
Speed
Detection
Level
Used when d1-18 = 0. If the speed
reference selected is lower than d1-
28, then the drive uses the leveling
speed as the speed reference.
d1-29
Inspection
Speed
Detection
Level
Used when d1-18 = 0. If the speed
reference selected is between d1-
28 and d1-29, then the speed refer-
ence is regarded as the Inspection
Speed, and the inspection opera-
tion sequence is activated.
No.
Name
Description
V/f Pattern for Motor 1
E1-01
Input Volt-
age Setting
This parameter must be set to the
power supply voltage.
WARNING! Drive input voltage
(not motor voltage) must be set in
E1-01 for the protective features of
the drive to function properly.
E1-04
Maximum
Output Fre-
quency
V/f pattern settings
For linear V/f characteristics, set
the same values to E1-07 and E1-
09. With these settings, the drive
will disregard the value set to E1-
08.
Parameters must be set so that:
E1-09
E1-07
E1-06
E1-04
E1-05
Maximum
Voltage
E1-06
Base Fre-
quency
E1-07
Mid Output
Frequency
E1-08
Mid Output
Frequency
Voltage
E1-09
Minimum
Output Fre-
quency
E1-10
Minimum
Output Fre-
quency
Voltage
E1-13
Base Volt-
age
Induction Motor Parameters
E2-01
Rated Cur-
rent
Motor data for Induction Motors.
Enter manually if Auto-Tuning
cannot be performed.
E2-02 Rated Slip
E2-03
No-Load
Current
E2-04
Number of
Motor Poles
E2-05
Line-to-Lin
e Resistance
E2-06
Leakage
Inductance
No.
Name
Description
Output Voltage (V)
Frequency (Hz)
E1-05
E1-13
E1-08
E1-10
E1-09
E1-07 E1-06
E1-04