5 Start Up
YASKAWA Europe
TOEP C710606 50B - AC Drive L1000V - Quick Start Guide
EN 25
5
Start Up
Drive Setup Procedure
The illustration below shows the basic setup procedure. The steps from switching on power
are explained in more detail on the following pages.
START
Apply main power on to the drive.
Adhere to safety messages concerning application of power.
Perform Auto-Tuning for motor parameters. Refer to Auto-Tuning
procedure on page 26 for more details
Perform a test run.
Fine-tuning
• Adjust settings for the brake sequence.
• Adjust speed control loop (C5-
) etc.
FINISH
Set up the
• Preset speed references (d1-
)
• Acceleration/deceleration ramp (C1-
)
• Jerk settings (C2-
)
Assign functions to the digital I/O terminals using
parameters H1-
and H2-
Set the Speed Reference Selection mode
parameter d1-18
Set up the Inspection Operation sequence.
Select the control mode in parameter A1-02.
Check the motor rotation direction.
Mechanical installation
Main and control circuit wiring