5-10
167646-1CD
HW1481264
5
I/O Signal Allocation
5.2 Transmission Data
Interface Board for Welding
Power Supply
5.2
Transmission Data
Data transferred from the JANCD-YEW01-E board to the DX200 are
16 contact inputs, 16 contact outputs, and 3 analog outputs (12 bit each).
The I/O data of the JANCD-YEW01-E board are allocated to the external
I/O signals of the concurrent I/O signals.
When only the JANCD-YEW01-E board is installed as an optional board,
the concurrent I/O of the board are allocated as shown below:
Concurrent I/O
JANCD-YEW01-E board
Welding power source
20010 to 22567
(2048 inputs)
30010 to 32567
(2048 outputs)
M560 to M561
(2 outputs)
Control by analog I/O
and contact I/O
M600 to M601
(2 inputs)
<Contact input>
<Contact output>
<Analog output>
<Analog input>
Contact input
Contact output
22550: GASOF (gas shortage) input
32550: System reservation
22551: WIRCUT (wire shortage) input
32551: ARCON (arc-ON) output
22552: ARCOFF (arc failure) input
32552: WIRINCH (wire inching) output
22553: ARCACT (arc establishment) input
32553: WIRRTR (wire retract inching) output
22554: STICK (wire stick) input
32554: System reservation
-
32555: Starting point detection command output
(optional)
22555 to 22557: System reservation
32556 to 32557: System reservation
22560 to 22567: System reservation
32560 to 32566: System reservation
-
32567: General output
Analog input
Analog output
M600: Channel 1
M560: Channel 1
M601: Channel 2
M561: Channel 2
31 of 40