7-9
Registers
Drive Parameter Registers (U2-XX / Fault Trace and U3-XX / Fault History)
REGISTER
PARAMETER
PARAMETER
PARAMETER
BIT
LIMITS / DESCRIPTION
(in hex)
FUNCTION
SETTING
NO.
080h
U2-01
Current Fault
Code of current fault (1)
081h
U2-02
Last Fault
Code of second to current fault (1)
082h
U2-03
Frequency Ref. at Fault
Frequency Reference at the time of the current fault (0.0 to 400.0 Hz)
083h
U2-04
Output Frequency at Fault
Output Frequency at the time of current fault (0.0 to 400.0 Hz)
084h
U2-05
Output Current at Fault
Output Current at the time of current fault (drive rating /8192)
085h
U2-06
Motor Speed at Fault
Motor Speed at the time of current fault (in 0.1 Hz)
086h
U2-07
Output Voltage at Fault
Output Voltage at the time of current fault (in 0.1 V)
087h
U2-08
DC Bus Voltage at Fault
Output Voltage at the time of current fault (in 1 V)
088h
U2-09
Output kWatts at Fault
Output Power at the time of current fault (in 0.1 kW)
089h
U2-10
Torque Reference at Fault
Torque Reference at the time of current fault (in 0.1%)
08Ah
U2-11
Input Terminal Status at Fault
0
Input Terminal 1 closed at time of fault
1
Input Terminal 2 closed at time of fault
2
Input Terminal 3 closed at time of fault
3
Input Terminal 4 closed at time of fault
4
Input Terminal 5 closed at time of fault
5
Input Terminal 6 closed at time of fault
6
Input Terminal 7 closed at time of fault
7
Input Terminal 8 closed at time of fault
08Bh
U2-12
Output Terminal Status at Fault
0
Control Circuit terminals 9 & 10: ìClosedî
1
Control Circuit terminals 25 & 27: ìClosedî
2
Control Circuit terminals 26 & 27: ìClosedî
3-6
not used
7
Control Circuit terminals 18 & 20: ìClosedî
Notes (for this page only):
1. List of Drive Error Codes can be found in Chapter 8, Error Codes and Troubleshooting.
Summary of Contents for GPD 515/G5 Modbus RTU
Page 1: ...GPD 515 G5 Modbus RTU Technical Manual ...
Page 24: ...6 4 The Message Format ...
Page 30: ...6 10 The Message Format ...