35
YASKAWA AC Drive
CR700
Catalog
|
KAEP C
710617
24
|
YASKAWA
Attachment for External Heatsink
Panel Modifi cation for External Heatsink
When the heatsink is installed
outside the drive, additional
attachments are required.
Additional attachments are not
required for models CR
70
A
2088
and above, and CR
70
A
4060
and
above because installing a
heatsink outside the drive can be
performed on these models by
replacing their standard
mounting feet.
Contact Yaskawa if an instruction
manual is needed.
Panel cut out dimensions
Catalog Code
CR
70A
Dimensions mm
Attachment for External
Heatsink Code No.
(Model No.)
W
H
D
1
D
2
W
1
W
2
W
3
W
4
H
1
H
2
H
3
H
4
H
5
A
B
d
1
2003
140
294
138
38
102
102
16
3
282
23
6
26
6
134
233
M
5
900-193-209-001
(
100-203-229
)
2005
2008
2011
2014
73
2018
2025
2033
2047
180
329
134
68
140
140
17
3
318
23.5
5
24.5
6
174
270
M
5
900-193-209-002
(
100-203-230
)
2060
220
384
140
87
192
192
11
3
371
27
7
25
6
214
319
M
6
900-193-209-003
(
100-203-231
)
2075
2088
240
400
166
114
195
204
14.5
8
385
19.5
7.5
19.5
7.5
224
346
M
6
―
2115
255
450
166
114
170
210
34.5
8
436
20
8
20
6
239
396
M
6
―
2145
264
543
186
149
190
220
29
8
527
19.5
8.5
20.5
7.5
248
487
M
8
―
2180
2215
312
700
260
160
218
263
39
8
675
33
12
32
13
296
610
M
10
―
2283
2346
440
800
254
218
370
310
23
12
773
31.5
14
31.5
13
416
710
M
12
―
2415
Catalog Code
CR
70A
Dimensions mm
Attachment for External
Heatsink Code No.
(Model No.)
W
H
D
1
D
2
W
1
W
2
W
3
W
4
W
5
W
6
H
1
H
2
H
3
H
4
H
5
A
B
d
1
4002
140
294
138
38
102
102
16
3
―
―
282
23
6
26
6
134
233
M
5
900-193-209-001
(
100-203-229
)
4003
4005
4006
73
4007
4009
4015
4018
4024
180
329
134
68
140
140
17
3
―
―
318
23.5
5
24.5
6
174
270
M
5
900-193-209-002
(
100-203-230
)
4031
4039
220
384
140
87
192
192
11
3
―
―
371
27
7
25
6
214
319
M
6
900-193-209-003
(
100-203-231
)
4045
106
4060
240
400
166
114
195
204
14.5
8
―
―
385
19.5
7.5
19.5
7.5
224
346
M
6
―
4075
255
450
166
114
170
210
34.5
8
―
―
436
20
8
20
6
239
396
M
6
―
4091
4112
264
543
186
149
190
220
29
8
―
―
527
19.5
8.5
20.5
7.5
248
487
M
8
―
4150
4180
312
700
260
160
218
263
39
8
―
―
675
33
12
32
13
296
610 M10
―
4216
4260
4304
440
800
254
218
370
310
23
12
―
―
773
31.5
14
31.5
13
416
710
M
12
―
4371
4414
510
1140
260
220
450
404
18
12
179
225
1110
34
15
34
15
486
1042 M12
―
4453
4605
400
V Class
200
V Class
H
H
1
W
D
1
D
2
W
1
W
2
B
A
W
4
W
4
H
2
H
3
H
5
W
3
W
3
W
1
A
Drill hole
×
4 (d1)
a
a
a
a
B
H
1
W
2
W
5
W
6
H
4
Note: The shaded area is the size when in installing the gasket.
Guarantee a wider and higher gasket width space than
the following W and H information.
Featur
es
Catalog Code /
Selecting the Capacity
Basic
Instructions
Standar
d
Specifi
cations
Standar
d
Connection Diagram
Terminal
Specifi
cations
Dimensions
Fully
-Enclosed
Design
Peripheral Devices
and Options
Application
Notes
Gl
o
b
a
l S
e
rv
ic
e
Ne
tw
o
rk
Fully
-Enclosed
Design