21
YASKAWA AC Drive
CR700
Catalog
|
KAEP C
710617
24
|
YASKAWA
400 V Class
*
1: For the most appropriate selection, contact your Yaskawa or nearest sales representative.
*
2: The value displayed is the input current when operating standard Yaskawa motors at the maximum applicable capacity with the rated load at the
rated motor speed. This value may fl uctuate based on the power supply side impedance, as well as the input current, power supply transformer,
input side reactor, and wiring conditions.
*
3: Rated input capacity is calculated with a power line voltage of 480 V.
Catalog Code CR
70A4
002
003
005
006
007
009
015
018
024
031
039
045
060
075
091
Max. Applicable
Motor Capacity
*
1
kW
0.4
0.75
1.5
2.2
3
3.7
5.5
7.5
11
15
18.5
22
30
37
45
Input
Rated Input
Current
*
2
A
1.9
3.5
4.7
6.7
8.9
11.7
15.8
21.2
30.6
41.3
50.5
43.1
58.3
71.5
86.5
Output
Rated Output
Current
A
1.8
3.4
4.8
5.5
7.2
9.2
14.8
18
24
31
39
45
60
75
91
Overload Tolerance
150% of rated output current for 60 s
Note: Derating may be required for applications that start and stop frequently.
Carrier Frequency
Derating the output current enables a maximum of
15 kHz to be set.
(Derating the output current is not necessary up to 8 kHz.)
Max. Output
Voltage
Three-phase
380 to 480 V
Note: The maximum output voltage is proportional to the input voltage.
Max. Output
Frequency
590 Hz
The frequencies that can be set vary depending on the control mode used.
Measures for
Harmonics
DC Reactor
External options
Built-in
Braking
Function
Braking Transistor
Built-in
EMC fi lter
EMC fi lter
EN
61800-3, C2/C3
Internal (factory option)
Power
Rated Voltage /
Rated Frequency
・
Three-phase AC power supply
380 V to 480 V 50/60 Hz
・
DC power supply
513 V to 679 V
Allowable Voltage
Fluctuation
−
15% to 10%
Allowable
Frequency
Fluctuation
±
5%
Power
Supply
*
3
kVA
1.5
2.8
3.7
5.3
7.1
9.3
13
17
24
33
40
34
46
57
69
Catalog Code CR
70A4
112
150
180
216
260
304
371
414
453
605
Max. Applicable
Motor Capacity
*
1
kW
55
75
90
110
132
160
200
220
250
315
Input
Rated Input
Current
*
2
A
105
142
170
207
248
300
373
410
465
584
Output
Rated Output
Current
A
112
150
180
216
260
304
371
414
453
605
Overload Tolerance
150% of rated output current for 60 s
Note: Derating may be required for applications that start and stop frequently.
Carrier Frequency
Derating the output current enables a maximum of
10 kHz to
be set.
(Derating the output current is not necessary up to 5 kHz.)
Derating the output current enables a
maximum of
5 kHz to be set.
(Derating the output current is not
necessary up to
2 kHz.)
Max. Output
Voltage
Three-phase
380 to 480 V
Note: The maximum output voltage is proportional to the input voltage.
Max. Output
Frequency
590 Hz
The frequencies that can be set vary depending on the control mode used.
Measures for
Harmonics
DC Reactor
Built-in
Braking
Function
Braking Transistor
Built-in
External options
EMC fi lter
EMC fi lter
EN
61800-3, C2/C3
Internal (factory option)
Power
Rated Voltage /
Rated Frequency
・
Three-phase AC power supply
380 V to 480 V 50/60 Hz
・
DC power supply
513 V to 679 V
Allowable Voltage
Fluctuation
−
15% to 10%
Allowable
Frequency
Fluctuation
±
5%
Power
Supply
*
3
kVA
84
113
136
165
198
239
297
327
370
465
Featur
es
Catalog Code /
Selecting the Capacity
Basic
Instructions
Standar
d
Specifi
cations
Standar
d
Connection Diagram
Terminal
Specifi
cations
Dimensions
Fully
-Enclosed
Design
Peripheral Devices
and Options
Application
Notes
Gl
o
b
a
l S
e
rv
ic
e
Ne
tw
o
rk
Standar
d
Specifi
cations