1 Introduction
1.2 System Overview
1-5
175932-1CD
175932-1CD
EcoTrim ET-1024 System
Fig. 1-2(a): FSU Generated “At Side A/B” Signals
Fig. 1-2(b): “Light Curtain Clear” or “At Side A/B” into E-Stop
This logic ensures that the table is located at “Side A” or “Side B” when the
light curtain is broken. If the curtain is broken when the table is out of
position (stopped or moving) the “External E-Stop” signal will open
resulting in a category#1 stop in either “Play” or “Teach” Mode.
The integrator or end-user may implement additional safety and zone
monitoring though the standard system which does not include FSU
functionality.
A three button post mounted operator station is located on the front right
fence post. This operator station provides a [Cycle Start] push button,
[Auto/Manual] selector switch, and an [E-Stop] button.
16 of 64