Length of user data for serial communication in byte.
Enter here the user data for the serial communication.
Bit 3...0
Reserved for receipt
Bit 7...4
n
8h: Acknowledgement: Idle state
n
9h: Acknowledgement: Fragmented transfer started
n
Ah: Acknowledgement: Data received without fragmentation
n
Ch: Status: Reset was executed on the CP
n
Dh: Status: The entered length is not valid
n
Eh: Status: Error in CP communication
–
there is no response of the other station
Host system
CP
Byte
Function
Byte
Function
0
Control-Byte
u
1...n-1
User data
t
0
Acknowledgement / Status
with n = number of used bytes in the address area (IO-Size)
Bit 3...0
n
0h...7h: Fragment number
n
8h: Idle state - no data available
n
Bh: Execute a reset on the CP
Bit 7...4
Reserved for receipt
Enter here the user data for the serial communication.
Bit 3...0
Reserved for receipt
Bit 7...4
n
0h...7h: Acknowledgement: Fragment number
n
8h: Acknowledgement: Idle state
n
Ch: Status: Reset was executed on the CP
n
Dh: Status: The entered length is not valid
n
Eh: Status: Error in CP communication
–
there is no response of the other station
Host system
CP
Byte
Function
Byte
Function
0
Control-Byte
u
1...n-1
User data
Length
User data
Acknowledgement Status
Write fragments
Control-Byte
User data
Acknowledgement Status
Write last fragment
VIPA System SLIO
Deployment
Principal communication via back plane bus > Sending data
HB300 | CP | 040-1CA00 | en | 18-28
45