Alarms and warnings
Not enough light:
The current irradiance
is too low to receive a suitable signal from
the N-Sensor optics.
The system switches to the preset uniform
application rate. After the alarm is ac-
knowledged, the low light level symbol (see
section 2.3.1) is displayed on the work
screen until the irradiance conditions have
improved. When this happens, the system
continues to apply the uniform rate until it is
switched back to sensor control manually.
No connection to N-Sensor:
The connec-
tion to the N-Sensor is lost. Either the N-
Sensor is not working properly or the con-
nection itself is faulty. Eventually the N-
Sensor is not powered properly.
The system switches to the preset uniform
application rate. After the alarm is ac-
knowledged, the no-N-Sensor-symbol (see
section 2.3.1) is displayed on the work
screen until the connection has been re-
established.
No connection to the variable-rate con-
troller:
The connection to the spreader or
sprayer is lost. Probably the controller is
not working properly or it is set up wrongly.
The system will be automatically deacti-
vated and stop data logging and sending
application rates.
To circumvent this warning, the
Unidirec-
tional only
option may be checked in the
Controller
page of the
System
menu (see
section3.3). With this option checked, no
warning will be generated at all, but as-
applied rates will not be logged.