background image

7

Graph 2

3. Annular anchors need to be deposited 60°to 80°along the base direction and check the

distance between the four hooks of the anchors and the center of the base. Four anchors

should be horizontal (as shown in the graph 3).

Graph 3

Summary of Contents for FD2.1-200-8L

Page 1: ...enzhou Wind driven Generator Co Ltd USER S MANUAL 2007 04 13 Yangzhou Shenzhou Wind driven Generator Co Ltd Add Xinhe Industrial Park Xiannv Town Jiangdu City Jiangsu Province Post code 225267 Phone 0...

Page 2: ...red Tower 13 Configuration Specification of Batteries 15 Electric Wiring 16 Maintenance 17 FAQS 17 Annex one Off grid Electric Wiring 19 Annex Two Controller Specification 3kw above 3kw 20 Annex Three...

Page 3: ...10H Rated power W 500W 1KW Rated voltage V 24 48 Rotor diameter M 2 5 2 1 2 7 2 3 Start up wind speed m s 2 2 Rated wind speed m s 8 12 9 12 Security wind speed m s 16 35 16 35 Rated rotating rate r...

Page 4: ...s 10 12 10 12 Security wind speed m s 25 45 25 45 Rated rotating rate r m 200 180 Blade material glass fiber glass fiber glass fiber glass fiber Blade quantity 3 3 Model FD10 0 20K 40H Rated power W...

Page 5: ...ter the distance is the less cable would be used As a result less energy waste would be produced during the transmission While under the circumstances of longer distance it s better to use much thicke...

Page 6: ...for the sake of easy adjustment Otherwise too tight or too loose fastening pull will lead to the curvature or even breakdown of tower while erecting the tower Step 3 Concrete the Foundation of Base a...

Page 7: ...r anchors need to be deposited 60 to 80 along the base direction and check the distance between the four hooks of the anchors and the center of the base Four anchors should be horizontal as shown in t...

Page 8: ...cables from the main section of tower near the tail edge 4 Fix the running flange and tower flange by bolts Hoist it by equipments such as pulleys chain block etc Pay attention that the generator axis...

Page 9: ...500w 1kw 2kw 30Nm 1 3kw 5kw 10kw 20kw 50Nm 1 Note Please keep to the above make sure If not we are not responsible for any possibility of breaking down the blades or flange 6 After adjusting the equa...

Page 10: ...both right and left sides should be directly connected to side anchor through turnbuckle Cable wire behind should be fixed on back anchor according to the same length Make sure there is no twist among...

Page 11: ...fixed wire cable to the one which is at least 16 meters Tie one end to the winch or tractor 2 Drill the wire cable or bracing cord through one end of the ladder 2 4 or 2 5 which will be served as sup...

Page 12: ...nd shakable The perfect force is neither too loose nor too tight and can be adjusted through circumrotating the bolt Installation specification of taper tower Step 1 Choosing installation sites Please...

Page 13: ...ersonnel Non working people should be far away from the site when hoisting 1 Utilized by supporter on the upper side of pole and hoist gradually 2 When the tower has been erected face the open hole on...

Page 14: ...120 240 360 Table 4 Electric Wiring 1 Off grid electric wiring annex 1 To ensure the safety and easy maintenance please install the switch and fuse according to the diagram Make sure there are consist...

Page 15: ...by local regulations What is more on grid controller and inverter need to be purchased additionally Maintenance Wind turbine may be operated under extremely harsh environment or meet various complicat...

Page 16: ...ltage of generator by a multi meter If the voltage is normal please check the batteries is ok otherwise check the wire of generator Why does not the rotor roll at a normal wind speed If the output wir...

Page 17: ...whether the dogvane is broken or not The concrete way is to unplug the plug of dogvane from controller and you will see there are three line on dogvane with marks Measure the resistance between and b...

Page 18: ...se contact us by phone or E mail The color of photographs may be different from real objects No notification if the manual modified The guarantee of turbine and controller is 2 years and the inverter...

Page 19: ...19 Annex 1 Off grid electric wiring...

Page 20: ...nd and achieve shutdown 4 The system will continuously check the batteries voltage when the system is under normal state of generating power The system will alarm automatically when over voltage or un...

Page 21: ...system will continually check battery voltage under normal operation state When over or under voltage the system will alarm automatically and send out the shutdown order Note anemoscope should be inst...

Page 22: ...d and wind scale together with alarming when the wind is weak or strong It consists of wind speed sensor FS10 wind speed scope FS100 and connecting wire The users can learn the local wind resource wit...

Page 23: ...23 Picture 10 Wind speed sensor FS10 Picture 11 Picture 11 Structural features Picture 12...

Page 24: ...ere will be alarming Press any key will make the alarming sound nonexistent 5 Over wind speed Wmax indicating light When the wind speed is under W Wmax state there will be alarming Press any key will...

Page 25: ...l enter into the setting menu of Wmin and Wmax as shown in the diagram 14 Setting way is the same as what mentioned in a c After having all the figures set press the function key once again the liquid...

Page 26: ...en under the state of W Wmin the alarming will be unchained W min return difference of under wind speed W min Wmin should be set If under wind speed alarming is not needed please set W min and Wmin on...

Page 27: ...uid crystal screen and keyboard contribute to the easy and convenient operation of FS200 It can also communicate with computer that is to record the data of wind speed and wind direction to computer w...

Page 28: ...FS200 3 Connecting FS200 to power supply 12V power supply is applied to FS200 Connect FS200 TO 12V power supply Special attention paid to the anode and cathode do not reverse them Check the wind speed...

Page 29: ...the move of cursor press to enter the menu option press to return to the up menu press to increase decrease the parameter MENU Picture 18 Picture 18 System time setting Pic19 Picture 19 to change the...

Page 30: ...history data 1min 60min adjustable Supposed that it is set 2minute and then the time of PH3000 can record is 8000 30min 24 hours 11 days Alarm set Picture 21 Picture 21 When wind speed exceeds the up...

Page 31: ...er and have the FS2000 computer software run The PH computer software is served as reading the present wind direction checked by dogvane Download the history data of wind direction saved by dogvane an...

Page 32: ...d rate on 9600bps and then open the serial Read the setting data Click the button of downloading the present setting to read data of the present wind speed and wind direction Or click pane before the...

Page 33: ...of Microsoft Access Users can observe and analyze history data of wind speed by table or curve view Setting system parameter Diagram 24 Diagram 24 Serve as reading or setting the system parameter of a...

Page 34: ...l record you need to check and then click the curve view The curve diagram of history record will be shown There are two types of displays namely overall display and partial display Diagram 26 Read th...

Page 35: ...35 Rose diagram of wind can illustrate the distribution and scope of different wind direction all the year round Diagram 27...

Reviews: