14
4. Suggested battery capacity for various model (as shown in the table 3)
Model
200W 300W 500W 1000W
2000W
3000W
5000W
10KW 20KW
Voltage of single battery (V)
12
Capacity of single battery(AH)
100
200
200
200
150
100
200
400
800
Quantity in series
2
2
2
4
10
20
20
20
30
Table 3
5. Charged parameter of batteries (as shown in the table 4)
Battery voltage(V)
12
24
36
48
120
240
360
Float charge voltage ( V)
15
30
45
60
150
300
450
Overvoltage ( V)
15
30
45
60
150
300
450
Over charge resume voltage ( V)
14
28
42
56
140
280
420
Undervoltage ( V)
10.5
21
32
42
105
210
315
Under charge resume voltage ( V)
12
24
36
48
120
240
360
Table 4
Electric Wiring
1. Off-grid electric wiring (annex 1)
To ensure the safety and easy maintenance, please install the switch and fuse according to the
diagram. Make sure there are consistent among the output voltages of generator, battery voltage
and input voltage of inverter. A wire-connecting mistake will lead to burn down the generator,
batteries and inverter.
(Special attention to 3kw & above 3kw)
a. There are two cables elicited from the generator head. One is the cable of wind direction signal
with aviation plug on cable head. You need to insert it into the socket. The other cable is for the
output of generator power and controlling signal. There are five lines with three relative thick
ones for generator output and the other two relative thin ones for controlling signal, which is