Display provided when Self-Diagnostic
Function started
The display is as described below depending on the
situation the last time the power to this unit is turned off.
When there is no history of protection function:
“1. DSP THR” is displayed. “11. VOL 0” menu is displayed
in a few seconds.
When there is a history of protection function:
The data of protection function which worked at the moment
is displayed for one second, and then the power is turned
off.
● ダイアグ起動時の表示
最後に本機の電源が切れたときの状況により、下記のよ
うに表示されます。
プロテクション履歴がない場合:
“1. DSP THR”が表示されます。数秒後、“11. VOL 0”メニュー
が表示されます。
プロテクション履歴がある場合:
そのときに働いたプロテクションの情報が 1 秒間表示さ
れた後、電源がオフになります。
●
Canceling Self-Diagnostic Function
1. Before canceling self-diagnostic function, execute
setting for “o. FACTORY PRESET” menu. (Memory
initialization inhibited or Memory initialized).
*
In order to keep the user memory preserved, be
sure to select PRESET INHIBIT (Memory initialization
inhibited).
2. Press the “ ” (Power) key to turn off the power.
● ダイアグの解除
1. ダイアグを解除する前に、“o. FACTORY PRESET” メ
ニュー(メモリーの初期化禁止/またはメモリーの
初期化)の設定をします。
※ ユ ー ザ ー メ モ リ ー を 保 持 し た い 場 合 は、 必 ず
PRESET INHIBIT(メモリー初期化禁止)を選択し
てください。
2. “ ”(電源)キーを押して電源を切ります。
For details of protection functions, refer to “l. PROTECTION
HISTORY” menu.
プロテクションの詳細は、“l. PROTECTION HISTORY” メ
ニューを参照してください。
Display /
表示
Display /
表示
Sub-menu display
サブメニュー表示
Power is turned off
電源オフ
Opening message /
オープニング表示
(Main menu /
メインメニュー
)
Opening message /
オープニング表示
(Protection function /
プロテクション情報
)
After a few seconds
数秒後
After one second
1 秒後
61
YSP-CU4300/YSP-CU3300/NS-WSW160
Y
SP-CU430
0/Y
SP-CU330
0/
NS-WSW1
60
DRAFT