3-47
CHK
ADJ
NOTE:
Since MF batteries are sealed, it is not possible
to check the charge state of the battery by mea-
suring the specific gravity of the electrolyte.
Therefore, the charge of the battery has to be
checked by measuring the voltage at the bat-
tery terminals.
1. Remove:
8
mat
8
battery cover
Refer to “COVER AND PANEL”.
2. Disconnect:
8
battery leads
(from the battery terminals)
c
C
First, disconnect the negative battery lead
1
1
1
1
1
, and then the positive battery lead
2
2
2
2
2
.
3. Remove:
8
battery
4. Check:
8
battery charge
*****************************************************
a. Connect a digital pocket tester
1
to the
battery terminals.
Pocket tester
90890-03132 (YU-03112-C)
Positive tester probe
J
positive battery terminal
Negative tester probe
J
negative battery terminal
NOTE:
8
The charge state of an MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive ter-
minal is disconnected).
8
No charging is necessary when the open-
circuit voltage equals or exceeds 12.8 V.
1
CHECKING AND CHARGING THE BATTERY
1
2