![Yamaha YBR250 2007 Service Manual Download Page 66](http://html.mh-extra.com/html/yamaha/ybr250-2007/ybr250-2007_service-manual_946314066.webp)
CHK
ADJ
3. While keeping the “MODE” button
1
pressed,
turn the starting switch to “ON”.
4. Press the “UP” button
4
and select “CO” to
change the “CO” or “DIAG” mode to diagnostic
mode.
5. After selecting “CO”, set the “MODE” button
1
.
6. Note that “C1” will be indicated on the display,
then press the “MODE” button
1
.
7. Start the engine.
ADJUSTING THE EXHAUST GAS VOLUME
1. Set the starting switch to “OFF” and the “engine
stop” switch to “ON”.
2. Disconnect the “self-diagnostic” signal terminal
1
and connect the injection diagnostic terminal
2
.
Be sure to set the CO density level to standard,
and then adjust the exhaust gas volume.
NOTE:
Injection diagnostic
90890-03182
•
"DlAG" will be indicated on the display
2
• The green LED “POWER”
3
is lighten
NOTE:
V
V
V
V
V
WARNING
Carry out the adjustments after being sure that
the battery is fully charged.
To adjust the exhaust gas volume, it is
necessary:
•
Gas analyzer;
•
Use forced vent addressed to the vehicle
engine when starting the engine.
3-10
ADJUSTING THE EXHAUST GAS VOLUME
2
1
1
2
3
4