Electrical technical data
2-10
RPS output voltage difference
0.1 V or less
RPS 1 Input voltage
4.75–5.25 V
RPS 2 Input voltage
4.75–5.25 V
ETV relay
Input voltage
12 V (battery voltage)
Cam position sensor
Input voltage
4.75–5.25 V
Output voltage (position a, c)
More than 4.8 V
Output voltage (position b)
Less than 0.8 V
Slant detection switch
Input voltage
4.75–5.25 V
Steering sensor
Input voltage
4.75–5.25 V
ECM unit
Input voltage
12 V (battery voltage)
Fuel system
Fuel injector
Input voltage
12 V (battery voltage)
Resistance
11.5–12.5
Ω
Fuel pump module
Input voltage
12 V (battery voltage)
Fuel sender
Lower position resistance
133.5–136.5
Ω
Upper position resistance
5.0–7.0
Ω
Starting system
Fuse
SCU
50 A
Battery
12 V, 30 A
Main relay
12 V, 20 A
Fuel pump relay
12 V, 10 A
ETV relay
12 V, 10 A
Remote control receiver
3 A
Starter motor
Type
Constant mesh
Output
0.60 kW
Cranking time limit
30.00 sec
Commutator diameter
28.0 mm (1.10 in)
Limit
27.0 mm (1.06 in)
Commutator undercut
0.7 mm (0.03 in)
Brush length
12.5 mm (0.49 in)
Wear limit
5.0 mm (0.20 in)
Summary of Contents for WaveRunner VXR VX1800A
Page 1: ...SERVICE MANUAL WaveRunner VXS VX1800 F2W VXR VX1800A F2W F2W 28197 ZU 11 ...
Page 12: ...How to use this manual 1 7 UP Upside YDIS Yamaha Diagnostic System Abbreviation Description ...
Page 40: ...Technical tips 1 35 MEMO ...
Page 163: ...Oil separator tank and oil pan 5 72 3 4 4 4 4 4 9 4 1 5 6 10 11 7 2 3 8 ...
Page 180: ...Crankcase connecting rod and piston 5 89 MEMO ...
Page 204: ...6 23 Intermediate housing Intermediate housing bolt 2 17 Nm 1 7 kgf m 12 5 ft lb 1 2 3 ...
Page 205: ...Intermediate housing 6 24 MEMO ...
Page 251: ...Indication system 7 44 MEMO ...
Page 278: ...8 25 Exhaust system 6 Install the band Rubber hose clamp 2 3 5 Nm 0 35 kgf m 2 58 ft lb ...
Page 290: ...Deck and hull 8 37 MEMO ...
Page 312: ...Engine unit troubleshooting 9 21 MEMO ...
Page 313: ...A Appendix Wiring diagram A 1 How to use the wiring diagram A 1 VXS VXR A 2 ...
Page 317: ......
Page 318: ...Mar 2015 CR E ...