8-6
–
+
ELEC
–
+
Ω×
1
W
W
W
b
IGNITION SYSTEM
CONDENSER (SX600/MM600)
1. Disconnect:
•
Condenser
1
2. Connect:
•
Condenser
(to the LCR meter)
3. Measure:
•
Condenser capacity
Out of specification
→
Replace.
Condenser capacity:
6,800
µ
F at 20
°
C (68
°
F)
SEA8040
SEA8050
SEA8060
AC MAGNETO
1. Disconnect:
•
AC magneto couplers
1
2. Connect:
•
Pocket tester
(to the AC magneto coupler)
3. Measure:
•
Pickup coil resistance
a
•
Stator coil resistance
b
Out of specification
→
Replace.
Pickup coil resistance:
(White/Red – White/Green)
189 ~ 231
Ω
at 20
°
C (68
°
F)
Stator coil resistance:
(White – White)
0.36 ~ 0.44
Ω
at 20
°
C (68
°
F)
Summary of Contents for VX600ERG
Page 1: ...VX600ERG SX600G MM600G VT600G SERVICE MANUAL LIT 12618 02 20 8EA 28197 10 981059 ...
Page 57: ...2 43 INSP ADJ CARBURETORTUNING Guide for carburetion SEA2720 ...
Page 79: ...2 65 INSP ADJ REAR SUSPENSION ...
Page 220: ...8 21 ELEC CHARGING SYSTEM ...
Page 236: ...8 37 ELEC SIGNAL SYSTEM ...
Page 266: ...9 20 SPEC GENERAL TORQUE SPECIFICATIONS DEFINITION OF UNITS ...
Page 267: ...SPEC 9 21 CABLE ROUTING SEA9010 ...
Page 269: ...SPEC 9 23 CABLE ROUTING SEA9010 ...
Page 271: ...SPEC 9 25 CABLE ROUTING SEA9020 ...
Page 273: ...SPEC 9 27 CABLE ROUTING SEA9030 ...
Page 275: ...SPEC 9 29 CABLE ROUTING SEA9030 ...
Page 277: ...SPEC 9 31 CABLE ROUTING SEA9040 ...
Page 279: ...SPEC 9 33 CABLE ROUTING SEA9050 ...
Page 281: ...SPEC 9 35 CABLE ROUTING SEA9050 ...
Page 283: ...SPEC 9 37 CABLE ROUTING SEA9060 ...
Page 287: ...Printed in USA E CR PRINTED ON RECYCLED PAPER ...