INSP
ADJUS
4. Check:
• The battery conditions
Check steps:
• Connect the voltmeter to the battery
terminals.
************************************
************************************
NOTE:
The conditions of a discharged MF battery
can be checked through the measurement
of the voltage in the open circuit (voltage
measured with the positive terminal
disconnected).
Open circuit voltage
Charging time
12.8 V or more
Charging not required
• Check the battery conditions according to
the instructions in the figures.
Example:
Open circuit voltage = 12.0 V
Charging time = 6.5 hours
Charge conditions of the battery = 20 ~
30%
5. Charging method for the MF battery:
CAUTION:
• If the standard current charge cannot be
stabilized, make sure not to exceed it.
• Remove the battery from the motorcycle
before charging it. (If, for any reason, it
is necessary to charge the battery on the
motorcycle, disconnect the negative
terminal.)
• The seal cap of MF batteries should never
be removed.
3-44
BATTERY INSPECTION
Testing terminal (+) => Battery
terminal (+)
Testing terminal (-) => Battery terminal
(-)