5
o
peration
5-31
5. Remote commands
5.1 Overview
Remote commands use the field network's remote register area to read and write various types of information,
and perform the positioning operation.
CC-Link
n
Inputs (Master
Remote)
Output (Remote
Master)
Address
Signal Name
Description
Address
Signal Name
Description
RWwn
WIN0
Execution command
RWrn
WOUT0
Status
RWwn+1
WIN1
Command option
RWrn+1
WOUT1
Command response
RWwn+2
WIN2
RWrn+2
WOUT2
RWwn+3
WIN3
RWrn+3
WOUT3
n: Value determined by CC-Link station No. setting.
DeviceNet, EtherNet/IP
n
Inputs (Master
Remote)
Output (Remote
Master)
Channel No.
Signal Name
Description
Channel No.
Signal Name
Description
m+2
WIN0
Execution command
n+2
WOUT0
Status
m+3
WIN1
Command option
n+3
WOUT1
Command response
m+4
WIN2
n+4
WOUT2
m+5
WIN3
n+5
WOUT3
"m", "n": These values are determined in accordance with the channel setting.
5.2 Remote command list
Query
n
Name
Command
Command Option
Command Response
WIN0
WIN1
WIN2, WIN3
WOUT1
WOUT2, WOUT3
Current position read
0100h
0000h
-
-
Current position
Current speed read
0100h
0001h
-
-
Operation speed
Electrical current read
0100h
0002h
-
-
Electrical current
Voltage read
0100h
0009h
-
-
Voltage
Temperature read
0100h
000Ah
-
-
Temperature
Current point No. read
0100h
000Dh
-
-
Operation-in-progress point No.
Load rate read
0100h
000Eh
-
-
Load rate
n
NOTE
• 2-word data is registered as the command response (Little Endian).
• When "8100h" is set for the command (WIN0), the query becomes the continuous query.