5
o
peration
5-25
3.10 Operation examples
Speed
Position
P2
(500mm)
P1
(200mm)
100%
100%
Setting example 1
Movement between 2 points, standard setting
A
B
23525-M0-00
No.
RUN type
Position [mm]
Speed [%]
Accel. [%]
Decel. [%]
Flag
P1
ABS
200
100
100
100
1
P2
ABS
500
100
100
100
0
A: P1 P2 positioning occurs.
B: Return to P1.
500.00mm/s
250.00mm/s
Speed
Position
P2
(500mm)
P1
(200mm)
Setting example 2
Movement between 2 points, custom setting
A
B
23526-M0-00
No.
RUN type
Position [mm]
Speed [%]
Accel. [%]
Decel. [%]
P1
ABS
200
250.00
4.00
100
P2
ABS
500
500.00
4.00
50
A: P1 P2 positioning occurs.
B: Return to P1.