signal functions
4-10
PZONE
n
This signal switches ON during a positioning operation when the current position enters the point data's "Zone+" and
"Zone-". After positioning ends, this signal remains enabled until the next positioning operation is executed.
This signal is enabled only when assigned to one of the OUT0 to OUT3 control outputs.
NEAR
n
This signal switches ON during a positioning operation when the current position enters tolerance distance range versus
the target position (the tolerance distance is specified by the point data's "Near Width" setting). After positioning ends,
this signal remains enabled until the next positioning operation is executed.
This signal is enabled only when assigned to one of the OUT0 to OUT3 control outputs.
TLM-S
n
This signal output is ON during a push operation.
This signal is enabled only when assigned to one of the OUT0 to OUT3 control outputs.
ORG-S
n
This signal output is ON when return-to-origin is complete, and is OFF when incomplete.
This signal is enabled only when assigned to one of the OUT0 to OUT3 control outputs.
ZONE
n
This signal switches ON only while the current position is within the zone specified by the "Zone (-)" and "Zone (+)"
parameters, and it can be used to verify the robot position at the host unit, or to identify zones where movement is
permitted or prohibited, etc.
This signal is enabled only when assigned to one of the OUT0 to OUT3 control outputs. It is disabled until a return-to-
origin is completed.
MOVE
n
This signal switches ON while movement is in progress (while the actual speed exceeds the "movement-in-progress"
output level (K12)). This signal is enabled only when assigned to one of the OUT0 to OUT3 control outputs.
/WARN
n
This signal remains OFF while a warning alarm is active, and is enabled only when assigned to one of the OUT0 to
OUT3 control outputs.
MANU-S
n
This signal switches ON when the MANUAL mode input switches ON, and switches OFF when the MANUAL mode
inputs switches OFF.
This signal is enabled only when assigned to one of the OUT0 to OUT3 control outputs.
READY (R-RDY)
n
This signal outputs the CC-Link communication status. This signal is ON when the communication status is normal. (This
signal is enabled only when using the CC-Link option.)