5-9-3. LCD-CONT (Contrast, Service Only)
Contents
Inspect the LCD contrast visually.
Confirm the change of the minimum
→
maximum
→
center luminance visually.
Advance preparation
None.
〈
Service inspection screen
〉
Left end
✽
is a selecting cursor.
A voltage measurement inspection is not conducted.
Inspect the lighting situation of backlight visually.
Contrast changes by pushing the Main knob.
This inspection is ended when it changes 3 times.
The fault location at the time of FAIL
LCD module
5-9-2. Panel
Contents
Inspect the LCD panel visually.
The following 16 patterns are displayed every 400
msec.
Seq
Display
Pattern
Data
(
1
)
(
9
)
Normal
Solid
0000..
(
2
) (
10
)
Normal
Solid
1111..
(
3
) (
11
)
Normal
Check
0101..
(
4
) (
12
)
Normal
Check
1010..
(
5
) (
13
)
Reverse
Solid
0000..
(
6
) (
14
)
Reverse
Solid
1111..
(
7
) (
15
)
Reverse
Check
0101..
(
8
) (
16
)
Reverse
Check
1010..
Advance preparation
None.
Note
The contrast (Electronic volume) value is typical.
〈
Service inspection screen
〉
Left end
✽
is a selecting cursor.
The fault location at the time of FAIL
The LCD module.