57
PX10/PX8/PX5/PX3
2-2-8. DP200 V-SENSE,I-SENSE Calibration
Measurement condition
Criteria
Select “Analog > CFG1
(
+14dBu
)
” with Service inspection mode.
Measured mode
/
8
Ω
MODE
Ampli
fi
er outputs are adjusted to 250W@8
Ω
Select “Analog > DP200 > V&I Calib-A, DP200 > V&I Calib-B” with Service
inspection mode.
The test program judge ‘PASS’ or ‘FAIL’ automatically.
※
When the calibration is completed successfully, it is
outputted as PASS.
※
Drive each channel.
2-2-9. Confirmation of DP200 V-SENSE
Measurement condition
Criteria
Select “Analog > CFG1
(
+14dBu
)
” with Service inspection mode.
Measured mode
/
8
Ω
MODE
Ampli
fi
er outputs are adjusted to 250W@8
Ω
Select “Analog > DP200 > V-SENSE-A, DP200 > V-SENSE-B” with Service
inspection mode.
The test program judge ‘PASS’ or ‘FAIL’ automatically.
※
Drive each channel.
2-2-10. Confirmation of DP200 I-SENSE
Measurement condition
Criteria
Select “Analog > CFG1
(
+14dBu
)
” with Service inspection mode.
Measured mode
/
8
Ω
MODE
Ampli
fi
er outputs are adjusted to 250W@8
Ω
Select “Analog > DP200 > I-SENSE-A, DP200 > I-SENSE-B” with Service
inspection mode.
The test program judge ‘PASS’ or ‘FAIL’ automatically.
※
Drive each channel.
2-2-11. Maximum Output 1 (STEREO Mode) (8Ω Mode /All channels drive)
Measurement condition
Criteria
Select “Analog > CFG1
(
+14dBu
)
” with Service inspection mode.
Measured mode
/
8
Ω
MODE
Refer to the “Setups at the time of maximum output measurement”(Page 59).
All channel
PX10
More than 243Vp-p
PX8
More than 227Vp-p
PX5
More than 179Vp-p
PX3
More than 139Vp-p
※
Drive all channels.