5-8-2. CFG2 (+4dBu)
Contents
Measure the output characteristic of ChA/ChB on
condition of the following.
PX10
PX8
PX5
PX3
Input Sensitivity
+4dBu
DP200 E-VOL
0dB
0dB
-2dB
-3dB
NJW1194 E-VOL
+16dB
Peak Limiter
OFF
1/8 Power Limiter
OFF
CLIP Limiter
OFF
AMP Prot Gain
0dB
Slicer
OFF
Regarding criteria for measurement, refer to “2-2. inspection”
(Page 54) of MEASUREMENT section.
Advance preparation
None.
〈
Service inspection screen
〉
Left end
✽
is a selecting cursor.
The fault location at the time of FAIL
Around DP200 (IC601) or NJW1194 (IC422)
5-8-3. CFG3 (Minimum volume)
Contents
Measure the output characteristic of ChA/ChB on
condition of the following.
PX10
PX8
PX5
PX3
Input Sensitivity
+14dBu
DP200 E-VOL
MUTE
NJW1194 E-VOL
-4dB
Peak Limiter
OFF
1/8 Power Limiter
OFF
CLIP Limiter
OFF
AMP Prot Gain
0dB
Slicer
OFF
Regarding criteria for measurement, refer to “2-2. inspection”
(Page 54) of MEASUREMENT section.
Advance preparation
None.
〈
Service inspection screen
〉
Left end
✽
is a selecting cursor.
The fault location at the time of FAIL
Around DP200 (IC601) or NJW1194 (IC422)