Edit
MONTAGE Reference Manual
91
Reference
Polarity (Curve Polarity)
Determines the Curve Polarity of the Curve type set in “Curve Type.”
Settings:
Uni, Bi
Uni:
Unipolar changes only in a positive direction or in a negative direction from a base parameter value according
to the Curve shape.
Bi:
Bipolar changes in both of positive and negative directions from a base parameter value.
Ratio (Curve Ratio)
Determines the Curve Ratio.
Settings:
-64 – +63
Param 1/Param 2 (Curve Parameter)
Adjusts the Curve shape.
This is not available depending on the Curve Type.
Destination to Name
Copies the Parameter name from “Destination” to “Display Name.” This is available only when “Source” is
set to “AsgnKnob 1 – 8.”
Delete
Deletes the selected “Destination.”
Edit User Curve
Calls up the User Curve Setting display. You can select “Linear” (Curve by Linear Interpolation of eight
coefficients) or “Step.”
Curve No. (Curve Number)
Indicates the selected Curve Number.
Settings:
1 – 32
Curve Name
Names the selected Curve. Touching the parameter calls up the input character display.
Curve Type
Determines the Curve Type.
Settings:
Linear, Step
Input
Determines the Input level of the Curve. “Input 1” is fixed to “0.” “Input 8” is fixed to 127 when the Curve
Type is “Linear.”
Settings:
0 – 127