8-47
Tester (+) lead
Black / Red terminal
Tester (–) lead
Frame ground
3. Oil level switch
Drain the engine oil and remove the oil level
switch from the oil pan.
Connect the pocket tester (
Ω
1) to the oil
level switch.
Check the oil level switch for continuity.
Replace the oil level switch.
NO CONTINUITY
1
4. Diode (starting circuit cut-off relay)
Remove the relay unit from the wire har-
ness.
Check for continuity as follows:
White / Black
– Black
Replace the relay unit.
CORRECT
INCORRECT
CONTINUITY
2
1
Tester (+) lead
White / Black
Tester (–) lead
Black
1
Tester (+) lead
Black
Tester (–) lead
White / Black
Continuity
No
Continuity
2
1
2