ELEC
Electrical systems
–
+
8-9
6D55F11
Checking the charge coil
1.
Measure the charge coil output peak volt-
age. Replace the stator coil if below
specification.
Checking the power bobbin
1.
Measure the power bobbin output peak
voltage. Replace the stator coil if below
specification.
Checking the lighting coil
1.
Measure the lighting coil output peak
voltage. Replace the stator coil if below
specification.
Digital circuit tester: 90890-03174
Peak voltage adapter B:
90890-03172
Charge coil output peak voltage:
Green/white (G/W) –
White/green (W/G)
r/min
Unloaded
Loaded
Cranking
1,500
3,500
DC V
170
130
140
140
Charge coil resistance
(reference data):
Green/white (G/W) –
White/green (W/G)
660–710
Ω
at 20 °C (68 °F)
Digital circuit tester: 90890-03174
Peak voltage adapter B:
90890-03172
Power bobbin output peak voltage:
Yellow/black (Y/B) –
Yellow/black (Y/B)
r/min
Unloaded
Cranking
1,500
3,500
DC V
10.0
38.9
80.0
r/min
Loaded
Cranking
1,500
3,500
DC V
5.5
30.0
80.0
Power bobbin resistance
(reference data):
Yellow/black (Y/B) –
Yellow/black (Y/B)
6.50–7.20
Ω
at 20 °C (68 °F)
Digital circuit tester: 90890-03174
Peak voltage adapter B:
90890-03172
Lighting coil output peak voltage:
Yellow (Y) – Yellow (Y)
r/min
Unloaded
Cranking
1,500
3,500
DC V
9.4
46.0
95.0
Summary of Contents for F2.5C
Page 1: ...F25C SERVICE MANUAL 6D5 28197 5F 11 290539 ...
Page 4: ......
Page 16: ...GEN INFO General information 1 11 6D55F11 MEMO ...
Page 27: ...6D55F11 2 10 1 2 3 4 5 6 7 8 9 Clamp bracket Maintenance specification ...
Page 112: ...POWR Power unit 5 51 6D55F11 MEMO ...
Page 136: ...LOWR Lower unit 6 23 6D55F11 Shimming 6 S6D56370 T3 A3 B3 42 5 T1 T2 24 0 24 0 B2 A1 A2 B1 ...
Page 173: ...6D55F11 TRBL SHTG 1 2 3 4 5 6 7 8 9 Troubleshooting Power unit 9 1 ...
Page 183: ......
Page 184: ...YAMAHA MOTOR CO LTD Printed in Japan Nov 2003 0 4 1 CR E Printed on recycled paper ...