2-21
INSP
ADJ
DC CIRCUIT BREAKER/
DC CIRCUIT BREAKER (120 V-60 Hz)
DC CIRCUIT BREAKER
1. Check:
•
DC circuit breaker
Checking steps:
•
Check if the DC circuit breaker knob
1
is
set to
“
RESET
”
“
”
a
.
•
If the knob
1
is set to
“
OFF
”
“
”
b
,
direct current cannot be supplied.
•
Start the engine.
•
Connect a pocket tester (DC 20 V) to the
DC receptacle and check if direct current
is supplied.
Direct current not supplied
→
Replace or
refer to
“
GENERATOR SYSTEM
”
in
CHAPTER 4.
Pocket tester:
YU-03112-C, 90890-03112
1
a b
SWL2080T
SWL2090T
DC CIRCUIT BREAKER (120 V-60 Hz)
1. Check:
•
DC circuit breaker
Checking steps:
•
Set the DC circuit breaker
1
to the posi-
tion of
“
ON
”
a
.
•
Connect the pocket tester (DC 20 V).
•
Start the engine.
•
Set the economy switch to
“
OFF
”
.
•
Measure the DC voltage.
•
Set the DC circuit breaker
1
to
“
OFF
”
b
.
Voltage is zero
→
OK
Pocket tester:
YU-03112-C, 90890-03112
DC voltage:
More than 12 V at 3,550 r/min
(no load at AC output current)
DC
ON
OFF
ON
1
a
b
SVU2330C
SWL2100T