4-19
–
+
ELEC
CHARGING SYSTEM
C0NTINUITY
CONTINUITY
5. Rectifier
•
Disconnect the rectifier connector.
•
Connect the pocket tester (
Ω
×
1) to the
rectifier.
•
Check the rectifier for continuity.
Normal
Tester positive lead
→
White
1
Tester negative lead
→
Red
2
Continuity
Tester positive lead
→
Red
2
Tester negative lead
→
White
1
No Continu-
ity
*
1
2
SWL4135
NO CONTINUITY
Replace the rectifier.
6. Wire harness (charging system)
Check the terminal of the connector for
contamination or rust, and the connector
for proper connection.
DISCONNECTED
Correct or replace the connector.