![Yamaha EF3000iSE - Inverter Generator - 3000 Maximum AC Output Service Manual Download Page 116](http://html.mh-extra.com/html/yamaha/ef3000ise-inverter-generator-3000-maximum-ac-output/ef3000ise-inverter-generator-3000-maximum-ac-output_service-manual_901747116.webp)
4-18
–
+
ELEC
CHARGING SYSTEM
C0NTINUITY
OUT OF
SPECIFICATION
3. Charging voltage
•
Start the engine.
•
3,800 r/min (no load)
•
Measure the charging voltage.
Tester positive lead
→
positive terminal
1
Tester negative lead
→
negative terminal
2
Charging voltage:
12 ~ 16 V
*
1
2
MEETS SPECIFICATION
Properly connect the charging system.
GOOD
4. Charging coil resistance
•
Disconnect the charging coil connector.
•
Connect the pocket tester (
Ω
×
1) to the
charging coil.
Tester positive lead
→
White terminal
1
Tester negative lead
→
Ground
2
Charging coil resistance:
White-Ground:
0.35
Ω
± 20% at 20 °C (68 °F)
*
2
1
SWL4130J
OUT OF SPECIFICATION
Replace the charging coil.