![Yamaha EF3000iSE - Inverter Generator - 3000 Maximum AC Output Service Manual Download Page 41](http://html.mh-extra.com/html/yamaha/ef3000ise-inverter-generator-3000-maximum-ac-output/ef3000ise-inverter-generator-3000-maximum-ac-output_service-manual_901747041.webp)
2-29
INSP
ADJ
BATTERY ELECTROLYTE/
BATTERY CHARGING
2. Check:
• Using a digital voltmeter, the state of a
discharged MF battery can be checked
by measuring open-circuit voltage (the
voltage measured with the positive and
negative terminals being disconnected).
CAUTION:
The battery must be charged after it is filled
with electrolyte. If this is not done, the life
of the battery will be shortened drastically.
BATTERY CHARGING
1. Check:
• Battery voltage
Check the battery voltage using an MF
battery tester (commercially available).
Within green range
→
Correct
Within yellow or red range
→
Charge
the battery.
2. Recharge the battery using an MF battery
charger (commercially available).
• Charge the battery to the specified
electric current and to the specified volt-
age.
Charging amperage and charg-
ing time:
1.2 A
×
5 ~ 10 hr
Charging voltage:
12.8 V or more
SWL2380J
SWL2390J