5-6
SPEC
MAINTENANCE SPECIFICATIONS
GENERATOR AND ELECTRICAL
Unit
EF2800i
Generator:
Main coil AC voltage (3 phase)
(V/r/min)
(With the throttle control motor coupler dis-
connected)
130 ~ 160/2,800
Sub coil AC voltage (single phase)(V/r/min)
(With the throttle control motor coupler dis-
connected)
13.5 ~ 23.0/2,800
Coil resistance
Main coil
(
Ω
± 10%)
0.6 (Yellow-Yellow)
Sub coil
(
Ω
± 10%)
0.14 (Orange-Orange)
DC charge coil
(
Ω
± 10%)
0.5 (Blue-Blue)
Electrical:
Ignition system
AC-CDI (voltage)
Pulser coil resistance
(
Ω
± 20%)
185
Ignition timing at 3,800 r/min
BTDC 23°
Primary coil resistance
(
Ω
± 15%)
0.11
Secondary coil resistance
(k
Ω
± 20%)
6.7
Charge coil resistance
(
Ω
± 10%)
(ignition source)
0.5
Spark plug cap resistance
(k
Ω
)
4.0 ~ 6.0
Minimum spark gap
mm (in)
6 (0.24)
Summary of Contents for EF2800i - Inverter Generator
Page 1: ...SERVICE MANUAL EF2800i LIT 19616 00 92 7VU 28197 10 310115 ...
Page 2: ......
Page 8: ......
Page 28: ......
Page 101: ......
Page 102: ...PRINTED ON RECYCLED PAPER PRINTED IN USA YAMAHA MOTOR CO LTD E ...