3-42
ENG
TROUBLESHOOTING
TROUBLESHOOTING
ENGINE DOES NOT START
Check that the oil warning
light turns ON by pulling the
starter rope.
Check connections between oil warning
unit and oil level switch.
Replace oil warning
light, oil warning
unit, or oil level
switch.
LIGHT ON
DOSE NOT
TURN ON
GOOD
NOT GOOD
Check engine oil level.
SUFFI-
CIENT
INSUFFI-
CIENT
Add.
Check fuel level.
INSUFFI-
CIENT
Add.
SUFFICIENT
Check if fuel is deteriorated.
GOOD
NOT GOOD
Replace.
Check fuel cock lever posi-
tion.
“ON”
“OFF”
Set to “ON”.
Check if fuel travels to fuel
cock.
Clean fuel tank and
fuel cock.
GOOD
NOT GOOD
• Check spark plug for dirt and check
spark plug gap.
• Check for voltage leakage due to faulty
connection or broken insulation of the
high tension cord.
• Check AC-CDI unit connector for corro-
sion or faulty connection.
• Check the ignition system. Refer to
“IGNITION SYSTEM” in CHAPTER 4.
Remove spark plug, attach
it to spark plug cap, and
then ground the spark plug
to check for spark.
GOOD
SPARK
WEAK OR
NO SPARK
Clean.
Correct.
Replace.
GOOD
NO GOOD
Install a substitute AC-CDI unit to check
spark conditions.
*
GOOD SPARK
WEAK OR NO
SPARK
Replace original
AC-CDI unit.