2-14
INSP
ADJ
RECEPTACLE/DC CIRCUIT BREAKER
RECEPTACLE
1. Check:
• AC receptacles (20 A)
1
• AC receptacle (30 A)
2
• DC receptacle (12 V, 10 A)
3
Cracks/damage
→
Replace.
Poor connection
→
Correct.
OVER
LOAD
BATTERY
CHARGE
ONLY
12V10A
RESET
AC RESET METHOD:
ENGINE PAUSE
20A
OFF
DC
PROTECTOR
DC
AC~
7VU
-40
2
1
3
SVU2320
DC CIRCUIT BREAKER
1. Check:
• DC circuit breaker
Checking steps:
• Press the reset button
1
to the position of
“RESET”
a
.
• Connect the pocket tester (DC 20 V).
• Start the engine.
• Set the economy switch to “OFF”.
• Measure the DC voltage.
• Set the reset button to “OFF”
b
.
Voltage is zero
→
OK
Pocket tester:
YU-03112, 90890-03112
DC voltage:
More than 12 V at 3,550 r/min
(with no load at AC output cur-
rent)
N.
AC
OVER
LOAD
BATTERY
CHARGE
ONLY
12V10A
RESET
OFF
DC
PROTECTOR
DC
1
a b
SVU2330
BATTERY
CHARGE
ONLY
RESET
OFF
DC
PROTECTOR
SVU2340