ENG
VALVE
3. Measure:
• Valve stem runout
Out of specification
→
Replace.
NOTE:
The value is half of that indicated on the dial
gauge.
Runout limit:
0.01 mm (0.0004 in)
SVU3200
4. Measure:
• Valve spring free length
a
Out of specification
→
Replace.
Valve spring free length:
Intake and exhaust: 26.5 mm
(1.04 in)
Limit: 25.0 mm (0.98 in)
SVU3210
5. Measure:
• Valve spring tilt
a
Out of specification
→
Replace.
Tilt limit:
1.6 mm (0.06 in)
SVU3220
6. Inspect:
• Valve spring contact surface
More than 2/3 of the contact surface
does not contact
→
Replace.