SET UP screen
— Reference Guide
19
• Library number 0 is a recall-only preset; data
cannot be stored in it. Data can be stored
only in library numbers 1–20.
• When you execute the Store operation, the
patching settings that had been stored in that
number will be erased.
I
LIBRARY No. (library number)
This area displays library numbers 00–20.
J
LIBRARY TITLE
This area displays the names assigned to the
library settings.
K
ROM
Recall-only library number 0 is indicated by a
write-prohibit symbol in this column.
L
Selected patching
The patching settings enclosed by the dotted
line in the library list will be the subject of the
Store or Recall operation. In this page, you can
use the [DATA/JOG] dial to select patching set-
tings regardless of where the cursor is located.
■
Additional functions in the Patch
Lib page
In the Patch Lib page you can press the [SHIFT] key
to assign the following functions to the [F1]–[F4]
keys.
• [F1] (CHANGE TAB) key
Switch between the two tab displays.
• [F2] (TITLE EDIT) key
Use this to edit the name (library title) of patch-
ing settings saved in the library. This is the same
function as the
6
TITLE EDIT button.
• [F3] (RECALL) key
Recall the currently selected patching settings
from the list. This is the same function as the
7
RECALL button.
• [F4] (STORE) key
Store the current patching settings. This is the
same function as the
8
STORE button.
●
To store the patching settings
into a library
[Procedure]
1. Access the SET UP screen Patch Lib page.
2. Use the [DATA/JOG] dial to select the
library number 1–20 into which you wish
to store the settings.
3. Move the cursor to the STORE button and
press the [ENTER] key.
The NAME EDIT display will appear, allowing
you to input the name.
Tip!
If STORE CONFIRMATION is turned “OFF”
in the UTILITY screen Prefer.1 page ([UTIL-
ITY] key
→
[F2] key), this popup window will
not appear.
4. Input the library title. For details on input-
ting characters, refer to Operation Guide
P.60.
5. Move the cursor to the OK button and
press the [ENTER] key.
The Store operation will be executed.
●
To recall patching settings from a
library
[Procedure]
1. Access the SET UP screen Patch Lib page.
2. Use the [DATA/JOG] dial to select the
library number that you wish to recall.
3. Move the cursor to the RECALL button
and press the [ENTER] key.
A confirmation message will appear.
Tip!
If RECALL CONFIRMATION is turned “OFF”
in the UTILITY screen Prefer.1 page ([UTIL-
ITY] key
→
[F2] key), this popup window will
not appear.
4. Move the cursor to the OK button and
press the [ENTER] key.
The Recall operation will be executed.
F1
F2
F3
F4