background image

19

ARTS Polling Time Options

The ARTS feature may be programmed to poll in 30 second (default value) or 1 minute 

intervals.

To change the polling interval:
1.  Press and hold the [

menu

] key.

2.  Rotate the 

DIAL

 knob to select [

03 AR INT

] then 

press the 

DIAL

 knob.

3.  Rotate the 

DIAL

 knob to select “

30 SEC

” or  

1 MIN

”.

4.  Press the 

DIAL

 knob to save the setting and return to normal operation.

Summary of Contents for FTM-6000R

Page 1: ...144 430MHz DUAL BAND FM TRANSCEIVER FTM 6000R FTM 6000E Advance Manual...

Page 2: ...stering a DTMF code 10 Transmitting the registered DTMF code 11 Functions to Use as Needed 12 Split Memory 12 Skip Memory Channels 13 Programmable Memory Channel Scan PMS 13 Registering to the Program...

Page 3: ...16 PKT SPD 29 17 RX MOD 29 18 BND SEL 29 19 RPT REV 29 20 RPT SET 30 21 RPT OTR 30 22 SCN ON 30 23 SCAN TYP 30 24 SQL TYPE 31 25 SQL CODE 31 26 SQL EXP 31 27 STEP 31 28 xx xxF C 32 29 TOT 32 30 TX PWR...

Page 4: ...select the desired setting The microphone gain level can be selected from 5 levels MIN LOW NORMAL HIGH MAX Default NORMAL 4 Press the DIAL knob to save the setting and return to normal operation Sett...

Page 5: ...rs the squelch opens and communication starts DCS Activates the Digital Code Squelch DCS function The DCS code may be selected from 104 codes from 023 to 754 PR FRQ Activates the no communication sque...

Page 6: ...elch opens the speaker audio only when a signal containing the specified CTCSS tone is received The receiver will be quiet while waiting for a call from a specific station Setting CTCSS Tone frequency...

Page 7: ...ct TON SQL 4 Press the SQL back key then rotate the DIAL knob to select 25 SQL COD 5 Press the DIAL knob 6 Press and hold the microphone UP or DWN switch The transceiver begins searching for a matchin...

Page 8: ...knob to select 24 SQL TYP then press the DIAL knob 3 Rotate the DIAL knob to select DCS 4 Press the SQL back key then rotate the DIAL knob to select 25 SQL COD 5 Press the DIAL knob then rotate the D...

Page 9: ...DCS 4 Press the SQL back key then rotate the DIAL knob to select 25 SQL COD 5 Press the DIAL knob 6 Press and hold the microphone UP or DWN switch The transceiver begins searching for a matching DCS...

Page 10: ...the DIAL knob to select 15 PAGER then press the DIAL knob PAG CDR is displayed on the screen 3 Press the DIAL knob 4 Rotate the DIAL knob to select the first tone of the code from 01 to 50 5 Press the...

Page 11: ...yed on the screen 3 Rotate the DIAL knob to the right PAG CDT is displayed on the screen 4 Press the DIAL knob 5 Rotate the DIAL knob to select the first tone of the code from 01 to 50 6 Press the DIA...

Page 12: ...ng Code Squelch just repeat the above procedure rotating the DIAL knob to select OFF in step 3 above Notification of a Call from a Remote Station by the Bell Function The Bell may be set to sound an A...

Page 13: ...Default MANUAL 4 Press the DIAL knob to save the setting and return to normal operation 5 While pressing and holding the PTT switch use the numeric keypad of the micro phone and press each digit of t...

Page 14: ...tered DTMF code 1 Press and hold the F menu key 2 Rotate the DIAL knob to select 09 DTMF then press the DIAL knob 3 Rotate the DIAL knob to select AUTO Default MANUAL 4 Press the SQL back key 5 Rotate...

Page 15: ...FO 4 Press and hold the V M mw key 5 Rotate the DIAL knob to select the channel num ber that the receive frequency was registered to on step1 6 While pressing and holding the PTT switch press and hold...

Page 16: ...the frequencies between user defined lower and upper band limits Registering to the Programmable Memory Channels 50 sets of PMS memory channels L01 U01 to L50 U50 are available 1 Select the desired lo...

Page 17: ...n of the DIAL knob rotation If the scanner halts on an incoming signal the frequency will blink The signal is received until the signal fades out Two seconds after the signal fades out scanning resume...

Page 18: ...function to a programmable key P1 P2 P3 P4 on the mi crophone How to assign DW function 1 Press and hold the F menu key 2 Rotate the DIAL knob to select 14 MIC PGM then press the DIAL knob 3 Rotate th...

Page 19: ...the DIAL knob to save the setting and return to normal operation Recalling the weather channels Example When WX is assigned to P4 1 Press P4 on the microphone The WX function is activated and the weat...

Page 20: ...splay only While within range IN RNG will appear on the LCD while out of range OUT RNG will appear Default While within range IN RNG will appear on the LCD Every time a polling transmission is receive...

Page 21: ...n the microphone 1 Press and hold the F menu key 2 Rotate the DIAL knob to select 14 MIC PGM then press the DIAL knob 3 Rotate the DIAL knob to select the PGM P1 PGM P2 PGM P3 or PGM P4 key to assign...

Page 22: ...fault value or 1 minute intervals To change the polling interval 1 Press and hold the F menu key 2 Rotate the DIAL knob to select 03 AR INT then press the DIAL knob 3 Rotate the DIAL knob to select 30...

Page 23: ...transceiver from which data is to be copied press the DIAL knob 6 Rotate the DIAL knob to select CLN TX 7 On the transceiver to which data is to be copied press the DIAL knob RCV WAT is displayed on t...

Page 24: ...tput RX 1200 1200 bps packet data output PK SQL squelch control z z Data cable CT 163 MDIN 10 pin MDIN 6 pin Dsub 9 pin To the transceiver To the personal computer etc To the TNC etc PKD packet data i...

Page 25: ...curring in the personal computer When signals cannot be received normally keep the personal computer at a distance away from the radio and use a photo coupler and noise filter to connect z z DATA comm...

Page 26: ...by are assigned to the function list that is displayed by pressing F menu key With the factory default setting F 12 HOME F 19 RPT REV F 20 RPT SET and F 30 TX PWR are assigned to the function list To...

Page 27: ...GIN Adjust the microphone gain level MIN LOW NORMAL HIGH MAX 14 MIC PGM PGM P1 Program the function assigned to the Mi crophone P1 key ARTS SCN ON HOME RPT SFT RPT REV TX PWR SQL OFF T CALL DW WX Defa...

Page 28: ...ble the split CTCSS DCS coding OFF ON 27 STEP Set the frequency synthesizer steps AUTO 5 6 25 8 33 10 12 5 15 20 25 50 100 kHz 8 33 kHz only for Air band 28 xx xF C Indicates the current temperature i...

Page 29: ...issued only when the radio first confirms that the stations are out of range but does not re confirm with beeps thereafter OUTRNG While within range IN RNG will appear on the LCD The beeps are issued...

Page 30: ...Func tion page 9 07 CLK TYP Set the CPU clock shift function The CPU Clock Shift function may be activated to eliminate an internally generated spurious high frequency signal Select TYP A for normal u...

Page 31: ...icrophone MIN LOW NORMAL HIGH MAX MIN Mic gain low MAX Mic gain high While pressing the PTT switch the microphone gain level may be adjusted 14 MIC PGM Set the microphone programable keys Functions ca...

Page 32: ...mode or AM mode is automatically se lected according to the frequency band in use FM The selected frequency band is set to FM mode AM The selected frequency band is set to AM mode 18 BND SEL Set up b...

Page 33: ...r shift offset frequency RPT FRQ Set the Repeater Shift offset frequency Set the repeater shift offset frequency 0 00MHz 99 95MHz Repeater shift offset frequency 0 00MHz 99 95MHz 22 SCN ON Scan freque...

Page 34: ...g the Squelch Type page 2 25 SQL CODE Set tone frequency or DCS code The tone frequency may be selected from 50 frequencies from 67 0 Hz to 254 1 Hz For more details see Setting CTCSS Tone frequency p...

Page 35: ...ter transmitting continuously for the set period of time The beep sounds at about 10 seconds before returning to receive mode automatically 30 TX PWR Select the transmit power output level The transmi...

Page 36: ...vice List Displays a list of registered or searched Bluetooth devices You can select and con nect a Bluetooth headset For details refer to Bluetooth Operation in the Operating Manual BLT SAV Bluetooth...

Page 37: ...without the permission of YAESU MUSEN CO LTD YAESU MUSEN CO LTD Tennozu Parkside Building 2 5 8 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan YAESU USA 6125 Phyllis Drive Cypress CA 90630 U S A...

Reviews: