— 27 —
of the Device, and then use it as a template for further configuration.
Table 1 below lists the full set of configuration parameters to be included in the configuration file. Vertical
lines in the list of arguments mean that only one of the values should be specified. Square brackets are used
to group the arguments.
Table 1. Configuration file parameters
Section
Parameter
Notes
CFGRESET
(no arguments)
Resets all Device settings to their
default values. If this string is present
in the configuration file, all other
settings are ignored.
IMPORTANT! When you use
this parameter, all calculation results
for SoC, consumed ampere-hours,
time remaining, SoH are automatically
reset (1).
RESET_RULES
(no arguments)
Resets all digital switching rules
to their default state, i.e. NEVER
SHUNT_CUR=x
x — integer from 1 to
2500.
Factory setting: 50
External shunt rated current
in amperes. Specify this value
according to your actual shunt's
nominal settings.
SHUNT_VOL=x
x — integer from 50 to
100.
Factory setting: 75
External shunt voltage drop
in millivolts. Specify this value
according to your actual shunt's
nominal settings.